2026 is a generational handover year for AI silicon: NVIDIA moved Vera Rubin into production, AMD launched its Helios rack system and Google expanded TPU Ironwood. This roundup covers what businesses need to know, and more importantly, what these chips demand from a data center.
NVIDIA Vera Rubin: Blackwell’s successor
Rubin is the GPU that succeeds Blackwell, paired with a new Arm CPU called Vera. In mid-2026 NVIDIA confirmed the platform was in full production and shipping systems to major customers. Key published specs:
- Design: two compute dies on TSMC 3nm, roughly 336 billion transistors.
- Memory: 288 GB HBM4 per GPU, vs. 192 GB HBM3e on B200.
- AI performance: about 50 PFLOPS NVFP4 for inference and 35 PFLOPS for training per GPU.
- Interconnect: sixth-generation NVLink at 3.6 TB/s per GPU, double Blackwell.
- Vera Rubin NVL72 rack: 72 Rubin GPUs and 36 Vera CPUs, about 3.6 exaFLOPS NVFP4 for inference.
NVIDIA also introduced Rubin CPX, a separate GPU optimized for long-context inference. Note that NVIDIA revised some shipping specifications versus its initial announcements, so check the official datasheet before planning. On the roadmap, Rubin Ultra is expected in 2027 and the Feynman architecture in 2028.
Meanwhile, Blackwell Ultra (B300/GB300) is being deployed widely. In Vietnam, FPT AI Factory announced new infrastructure on NVIDIA HGX B300 in March 2026.
AMD Instinct MI450 and the Helios rack
At its Advancing AI event in July 2026, AMD launched Helios, a rack-scale system combining 72 liquid-cooled Instinct MI455X GPUs, 6th-gen EPYC “Venice” CPUs, Pensando networking and the ROCm software stack. Highlights:
- CDNA 5 architecture with HBM4; AMD has stated up to 432 GB of HBM4 per MI450-series GPU.
- Helios shipments began at the end of Q3 2026, ramping through 2027.
- OpenAI, Meta, Anthropic and Oracle have all announced deployment plans.
- AMD committed to an annual cadence: MI500 in 2027, MI600 in 2028.
Google TPU Ironwood and TPU 8
Ironwood is Google’s seventh-generation TPU, built for the “age of inference”. Each chip delivers about 4.6 PFLOPS FP8 with 192 GB HBM3e, and up to 9,216 chips can be combined in a superpod for roughly 42.5 exaFLOPS. At Cloud Next 2026, Google also previewed an eighth generation split into two chips — TPU 8t for training and TPU 8i for inference — targeting late 2027 on 2nm. Unlike GPUs, TPUs are only available through Google Cloud and cannot be installed in your own data center.
Quick comparison
| Chip | Vendor | Memory | How to access |
|---|---|---|---|
| Rubin (Vera Rubin) | NVIDIA | 288 GB HBM4 | Buy servers/racks for a DC, or rent in cloud |
| Blackwell Ultra B300 | NVIDIA | HBM3e | Widely deployed |
| Instinct MI455X (Helios) | AMD | HBM4 | 72-GPU liquid-cooled rack |
| TPU Ironwood | 192 GB HBM3e | Google Cloud only |
What does this mean for data centers?
Each new generation pushes power and heat density higher:
- Rack-scale systems: a GB200 NVL72 rack draws about 120 kW, and estimates for Blackwell Ultra NVL72 reach 135–140 kW. The Rubin platform is designed around full liquid cooling.
- 8-GPU servers: for most enterprises, the common building block is still the 8-GPU server such as DGX H100 (about 10.2 kW) or DGX B200 (about 14.3 kW), which fits well-designed high-density air-cooled racks.
When choosing GPUs, plan the infrastructure at the same time: power per rack, cooling approach and room to grow over the next 2–3 years.
If you are weighing which GPU generation to deploy and what your data center must support, contact us for a configuration-specific consultation.
References
- Data Center Dynamics – Nvidia announces Vera Rubin Superchip for late 2026
- GCN – NVIDIA Vera Rubin chips begin shipping to cloud providers
- ServeTheHome – NVIDIA revises Rubin shipping specifications
- Towards AI – B200 to Vera Rubin: what NVIDIA changed
- Network World – Nvidia GPU, CPU and system roadmap
- Data Center Frontier – AMD Helios takes AI infrastructure fight to rack scale
- Fierce Network – AMD launches full-stack AI compute
- Tom’s Hardware – AMD debuts Helios rack-scale platform
- The Next Web – Google Ironwood GA and TPU 8 split
- IntuitionLabs – NVIDIA HGX data center requirements (DGX B200 ~14.3 kW)
- NVIDIA Docs – DGX H100 User Guide: specifications (10.2 kW max, 8U)
- TechRepublic – Data center power and cooling trends (Omdia)